Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
ABC., imagem cardiovasc ; 35(2): eabc281, 2022. ilus, tab
Article in English, Portuguese | LILACS, CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1398019

ABSTRACT

BACKGROUND: Functional mitral regurgitation (FMR) is associated with dilated cardiomyopathy (DC), heart failure (HF), and worsening left atrial function (LAF). Patients with DC and FMR may present left atrial dysfunction resulting from both ventricular dysfunction and valve disease, but it is unknown whether the presence of valve disease will lead to greater LAF impairment. OBJECTIVE: This study aimed to evaluate the relationship between LAF parameters and FMR degree in patients with DC. METHODS: This cross-sectional observational study included 214 patients with DC, 46 without FMR (control group) and 168 with mild, moderate or severe FMR. An LAF analysis was performed by speckle tracking echocardiography (STE) and atrial volumetric variation. RESULTS: LAF analyzed by STE by means of reservoir strain, conduit strain and active contraction strain was reduced in the sample, with values of 14.3%, 8.49% and 5.92%, respectively. FMR degree was significantly associated with reservoir strain (0.27 ± 0.16 versus 0.15 ± 0.09; p < 0.001) and contraction strain (19.2 ± 7.3 versus 11.2 ± 2.7; p < 0.001). FMR was also associated with a reduced LAF assessed by volumetric analysis: total atrial emptying fraction of 0.51 ± 0.13 versus 0.34 ± 0.11 and active atrial emptying fraction of 0 .27 ± 0.16 versus 0.15 ± 0.09 (p < 0.001). CONCLUSION: In a population with DC, FMR was associated with reduced LAF assessed by STE and atrial volume variation.


FUNDAMENTO: A insuficiência mitral funcional (IMF) está associada à miocardiopatia dilatada (MD), à insuficiência cardíaca (IC) e à piora da função atrial esquerda (FAE). A FAE pode decair tanto pela disfunção ventricular quanto pela valvopatia, mas não se sabe se esta leva a um prejuízo maior da FAE. OBJETIVO: Avaliar a relação entre a piora de parâmetros de FAE com o grau de IMF, em pacientes com MD. MÉTODOS: Trata-se de estudo observacional transversal, que incluiu 214 pacientes com MD, sendo 46 sem IMF (controle) e 168 com IMF discreta, moderada ou grave. A análise da FAE foi realizada por ecocardiografia por speckle tracking (STE) e por variação volumétrica atrial. RESULTADOS: A FAE, analisada por STE­ por meio do strain de reservatório, conduto e contração ativa ­ encontrou-se reduzida na amostra, com valores respectivos de 14,3%, 8,49% e 5,92%. O grau de IMF associou-se significativamente com os valores do strain de reservatório (0,27±0,16 versus 0,15±0,09; p <0,001. CONCLUSÃO: Em uma população com MD, a presença de IMF associa-se à redução da FAE de reservatório e de contração, avaliada por STE e pela variação volumétrica atrial.


Subject(s)
Humans , Male , Middle Aged , Echocardiography/methods , Cardiomyopathy, Dilated/complications , Atrial Function, Left/physiology , Mitral Valve Insufficiency/physiopathology , Electrocardiography, Ambulatory/methods , Ventricular Dysfunction/complications , Ventricular Dysfunction/diagnostic imaging , Aortic Valve Disease/complications , Heart Failure/physiopathology
3.
Rev. bras. anestesiol ; 70(2): 134-139, Mar.-Apr. 2020. tab, graf
Article in English | CONASS, LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1137155

ABSTRACT

Abstract Introduction: Currently, transesophageal echodopplercardiography is frequently performed under sedation on an outpatient basis. Sedation is related with increase in incidents on airways. Bearing in mind this scenario, we developed a new double lumen oropharyngeal cannula aimed at keeping airway patency, in addition to reducing risks to patients during endoscopy procedures performed under sedation. The main objective of our study was to assess the incidence of oxygen desaturation in a series of cases of adult patients submitted to outpatient transesophageal echo exam, under sedation and using the oropharyngeal cannula. Method: 30 patients under sedation with intravenous midazolam and propofol were assessed. After loss of consciousness, the cannula was placed and patients were maintained on spontaneous breathing. Oxygen saturation, capnometry, heart rate and non-invasive arterial blood pressure, in addition to subjective data: airway patency, handling of cannula insertion and, comfort of examiner were analyzed. Results: The incidence of mild desaturation was 23.3%, and there was no severe desaturation in any of the cases. The insertion of the oropharyngeal cannula was considered easy for 29 patients (96.6%), and transesophageal echo probe handling was appropriate in 93.33% of exams performed. Conclusions: Transesophageal echo exams under sedation aided by the double-lumen oropharyngeal cannula presented a low incidence of desaturation in patients assessed, and allowed analysis of expired CO2 during the exams.


Resumo Introdução: Nos dias atuais, exames de ecocardiografia transesofágica (ETE) são realizados de forma frequente sob sedação em regime ambulatorial. A sedação está relacionada com aumento de intercorrências nas vias aéreas. Dentro desse contexto, desenvolvemos uma cânula orofaríngea de duplo-lúmen com finalidade de manutenção da via aérea pérvia, reduzindo riscos aos pacientes durante procedimentos endoscópicos sob sedação. O principal objetivo do nosso estudo foi avaliar a incidência de dessaturação em uma série de casos de pacientes adultos submetidos a ETE ambulatorial sob sedação com o uso da cânula orofaríngea. Métodos: Foram avaliados 30 pacientes sedados com midazolam e propofol intravenoso. A cânula foi inserida após perda da consciência e os pacientes foram mantidos com ventilação espontânea. Analisados saturação de oxigênio, capnometria, frequência cardíaca e pressão arterial não invasiva, além de dados subjetivos: patência das vias aéreas, manuseio e inserção da cânula e conforto ao examinador. Resultados: A incidência de dessaturação leve foi de 23.3% e não houve dessaturação grave em nenhum caso. A inserção da cânula orotraqueal foi considerada fácil em 29 pacientes (96,6%) e o manuseio da sonda de ETE foi adequada em 93,33% dos exames realizados. Conclusões: A realização dos exames de ETE sob sedação com auxílio da cânula orofaríngea de duplo lúmen apresentou baixa incidência de dessaturação nos pacientes avaliados, além de permitir análise do CO2 expirado durante a realização dos exames.


Subject(s)
Echocardiography , Cannula , Anesthesia and Analgesia , Conscious Sedation
5.
Int. j. cardiovasc. sci. (Impr.) ; 32(5): 460-470, Sept-Oct. 2019. tab, graf, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1040110

ABSTRACT

In atrial fibrillation (AF), the CHA2DS2-VASc score calculates the risk for stroke. Di Biase classified the left atrial appendage (LAA), using magnetic resonance imaging, into 4 morphological types and correlated it with cerebrovascular events. Transesophageal echocardiography (TEE) also evaluates LAA and is a more widespread technique. Objective: To evaluate, using TEE, the possibility of characterizing LAA and to analyze its morphological aspects using the CHA2DS2VASc score. Methodology: A total of 247 patients were divided into three groups considering the CHA2DS2-VASc score: Group 1: 0 and 1; Group 2: 2 and 3 and, Group 3: ≥ 4 points. TEE produced the echocardiographic data. LAA was classified into thrombogenic and non-thrombogenic morphologies. In the analysis of statistical tests, a significance level of 5% was adopted. Results: The average age was 50 and 16.2% presented AF. In Group 1, we observed normal variables with a lower prevalence of AF (8.7%, p < 0.001). In group 2, spontaneous contrast was detected in 26.7%, (p < 0.001), thrombus in 6.7% (p = 0.079) and flow velocity in LAA < 0.4 m/s in 22.7% (p < 0.001) of the cases. Group 3 presented the highest percentages of AF (31.8%, p < 0.001), stroke/TIA (77.3%, p < 0.001), EF < 55% (18.2%, p = 0.010) and higher prevalence of thrombogenic type LAA (72.7%, p = 0.014). A higher occurrence of stroke/TIA was observed in patients with thrombogenic LAA (25.2%) compared to the non-thrombogenic group (11.2%), (p = 0.005). Conclusions: The thrombogenic morphology of LAA identified in TEE presented a higher risk of stroke regardless of the CHA2DS2VASc score. Patients with higher scores had greater abnormalities in echocardiographic variables


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Atrial Fibrillation , Thrombosis , Echocardiography, Transesophageal/methods , Stroke/mortality , Stroke Volume , Magnetic Resonance Spectroscopy/methods , Tomography/methods , Data Interpretation, Statistical , Retrospective Studies , Risk Factors , Atrial Appendage , Diabetes Mellitus , Heart Failure , Hypertension
6.
ABC., imagem cardiovasc ; 31(4)Out.- Dez. 2018. tab, ilus, graf
Article in Portuguese | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-964021

ABSTRACT

Fundamento: Os refluxos paraprotéticos são complicações comuns após cirurgia de troca valvar. A quantificação da gravidade, a localização e a morfologia dos refluxos paraprotéticos podem ser demonstradas por meio da ecocardiografia transesofágica tridimensional. Objetivo: Avaliar a correlação entre gravidade da regurgitação paravalvar, avaliada pela ecocardiografia tradicional bidimensional, usando a largura da vena contracta, e as medidas derivadas da avaliação pela ecocardiografia transesofágica tridimensional (comprimento, largura e área); avaliar o sucesso terapêutico da oclusão de refluxos paraprotéticos, guiada por ecocardiografia transesofágica tridimensional, e a correlação entre as medidas desta e as dos dispositivos para oclusão percutânea. Método: Estudo retrospectivo de 11 pacientes consecutivamente submetidos ao tratamento percutâneo de refluxos paraprotéticos entre 2014 e 2015, avaliados por meio de ecocardiografia transtorácica e ecocardiografia transesofágica tridimensional, no pré-operatório e no intraoperatório. Resultados: De um total de 20 refluxos paraprotéticos, 18 apresentaram sucesso técnico imediato. Não houve correlação entre as medidas da vena contracta bidimensional e as derivadas da ecocardiografia transesofágica tridimensional. Houve correlação forte entre o comprimento do defeito pela ecocardiografia transesofágica tridimensional e o comprimento do dispositivo para oclusão percutânea (rho = 0,929; p < 0,001), além de correlação moderada entre a área do defeito e a do dispositivo para oclusão percutânea (rho = 0,682; p = 0,002). Não houve correlação entre a largura do dispositivo para oclusão percutânea e a do defeito medida pela ecocardiografia transesofágica tridimensional (rho = 0,440; p = 0,067). Conclusão: Não houve correlação entre a medida da vena contracta bidimensional e as medidas derivadas da ecocardiografia transesofágica tridimensional. A escolha dos dispositivos para oclusão percutânea baseada nas medidas da ecocardiografia transesofágica tridimensional apresentou alta taxa de sucesso imediato, com ótima correlação entre o comprimento dos defeitos e dos dispositivos para oclusão percutânea. A correlação entre as áreas foi boa e não houve correlação entre as larguras


Background: Paravalvular leaks are a common complication after valve replacement surgery. Quantification of the severity, location and morphology of paravalvular leaks can be obtained by three-dimensional transesophageal echocardiography. Objective: To evaluate the correlation between the severity of paravalvular regurgitation by vena contracta measurement using bidimensional echocardiography, and measurements derived from three-dimensional transesophageal echocardiography (length, width and area). To evaluate the therapeutic success of three-dimensional transesophageal echocardiography-guided paravalvular leaks occlusion and the correlation between three-dimensional transesophageal echocardiography measurements and dimensions of devices for percutaneous occlusion. Method: Retrospective study of 11 patients consecutively submitted to percutaneous paravalvular leaks treatment between 2014 and 2015, using transthoracic echocardiography and between three-dimensional transesophageal echocardiography in the preoperative and intraoperative periods. Results: Out of a total of 20 paravalvular leaks, 18 showed immediate technical success. There was no correlation between the measurements of the bidimensional vena contracta and the measures derived from the three-dimensional transesophageal echocardiography. There was a strong correlation between the defect length measured by the three-dimensional transesophageal echocardiography and the device for percutaneous occlusion length (rho = 0.929; p < 0.001); and moderate between the defect area and the device for percutaneous occlusion area (rho = 0.682,p = 0.002). There was no correlation between the device for percutaneous occlusion width and the defect width measured by three-dimensional transesophageal echocardiography (rho = 0.440; p = 0.067). Conclusion: There was no correlation between the measurement of the bidimensional vena contracta and the measures derived from the three-dimensional transesophageal echocardiography. The choice of devices for percutaneous occlusion based on three-dimensional transesophageal echocardiography measurements showed a high success rate, with an excellent correlation between defect length and devices for percutaneous occlusion length. The correlation between the areas was good, and there was no correlation between the widths


Subject(s)
Humans , Male , Female , Heart Valve Prosthesis , Echocardiography, Doppler, Color/methods , Heart Valves/surgery , Aortic Valve/surgery , Tertiary Healthcare , Prosthesis Failure/adverse effects , Data Interpretation, Statistical , Retrospective Studies , Perioperative Care , Tertiary Care Centers , Observational Study , Intraoperative Period , Mitral Valve/surgery
8.
ABC., imagem cardiovasc ; 30(3): f:87-l:91, jul.-set. 2017. tab, ilus
Article in Portuguese | LILACS | ID: biblio-848719

ABSTRACT

Introdução: Diferentes tecnologias têm sido utilizadas para avaliar a função sistólica do ventrículo esquerdo. De particular interesse, está a ecocardiografia com strain bidimensional (2DSTE). Dois métodos diferentes têm sido usados para quantificar a deformação miocárdica (strain miocárdico) pela 2DSTE: block matching e optical flow. Ambos estão presentes em ecocardiógrafos comercialmente disponíveis. Entretanto, não há consenso a respeito se as medidas do strain longitudinal por estes métodos são sobreponíveis. Objetivo: Comparar os valores de pico do strain miocárdico longitudinal obtidos através da 2DSTE pelos dois diferentes métodos (block matching x optical flow). Método: Foram realizadas as medidas do strain em 16 segmentos miocárdicos do ventrículo esquerdo, conforme orientação da Sociedade Americana de Ecocardiografia pela técnica do block matching (Vivid 7, GE, Horten, Noruega) e, imediatamente após, pela técnica do optical flow (My Lab 60, Esaote, Florença, Itália) de forma randomizada e seus valores foram comparados. Resultados: Houve 28 indivíduos com idade 27,9 ± 7,7 anos, sendo 50% do sexo masculino e todos com fração de ejeção superior a 55%. A medida do strain longitudinal global foi maior pela técnica de block matching (p = 0,02). Na análise dos 16 segmentos, houve 10 segmentos com valores diferentes, em especial os segmentos apicais. Conclusão: Os valores do strain miocárdico longitudinal obtidos por métodos diferentes não são sobreponíveis e devem ser usados com cautela. Sendo assim, valores de normalidade também variam de acordo com o fabricante e o método utilizado


Introduction: Different technologies have been used to evaluate left ventricular systolic function. Of particular interest is the two-dimensional strain echocardiography (2DSTE). Two different methods have been used to quantify myocardial strain by 2DSTE: block matching and optical flow. Both are present in commercially available echocardiographs. However, there is no consensus as to whether the longitudinal strain measures using these methods are overlapping. Objective: To compare the longitudinal myocardial strain peak values obtained through 2DSTE using two different methods (block matching x optical flow). Method: Strain measurements in 16 left ventricular myocardial segments were taken as recommended by the American Society of Echocardiography using block matching (Vivid 7, GE, Horten, Norway) and, immediately after, using optical flow (My Lab 60, Esaote, Florence, Italy) in a randomized way and their values were compared. Results: There were 28 individuals aged 27.9 ± 7.7, of whom 50% were male and all with an ejection fraction greater than 55%. Global longitudinal strain was higher using block matching (p = 0.02). In the analysis of the 16 segments, 10 segments had different values, especially the apical segments. Conclusion: Longitudinal myocardial strain values obtained by different methods are not overlapping and must be used with caution. Normality values also vary according to the manufacturer and the method used


Subject(s)
Humans , Male , Female , Adult , Diagnostic Imaging/methods , Echocardiography, Doppler/methods , Image Processing, Computer-Assisted/methods , Cardiovascular Diseases/complications , Cardiovascular Diseases/diagnosis , Heart Diseases/diagnosis , Heart Ventricles , Risk Factors , Data Interpretation, Statistical , Stroke Volume
9.
Rev. bras. ecocardiogr. imagem cardiovasc ; 26(3): 223-227, jul.-set. 2013. ilus
Article in Portuguese | LILACS | ID: lil-683655

ABSTRACT

Apesar de pouco frequente, a ruptura de músculo papilar é uma condição associada à regurgitação mitral importante, sendo causa grave de insuficiência cardíaca aguda, necessitando de diagnóstico e intervenção cirúrgica precoce. Neste relato, apresentamos um caso de paciente portador de febre reumática associado à endocardite infecciosa, que evoluiu com insuficiência mitral importante, secundária à ruptura do músculo papilar anterolateral.


Although its low frequency, the papillary muscle rupture is a condition associated with severe mitral regurgitation and cause of acute heart failure and need for urgent surgical intervention. We present a case of severe mitral regurgitation due to the anterolateral papillary muscle rupture secondary to rheumatic mitral valve disease and infectious endocarditis.


Subject(s)
Humans , Female , Adult , Endocarditis/complications , Rheumatic Fever/complications , Mitral Valve Insufficiency/complications , Papillary Muscles/pathology , Echocardiography/methods , Echocardiography , Electrocardiography/methods , Electrocardiography , Risk Factors
11.
Arq. bras. cardiol ; 100(4): 368-375, abr. 2013. ilus, tab
Article in Portuguese | LILACS, SES-SP | ID: lil-674198

ABSTRACT

FUNDAMENTO: A plástica valvar mitral é o procedimento cirúrgico de escolha para pacientes com Insuficiência Mitral (IM) crônica. Os bons resultados imediatos e tardios permitem a indicação cirúrgica antes do início dos sintomas. O teste cardiopulmonar de exercício (TCPE) pode avaliar objetivamente a capacidade funcional, mas pouco se conhece o efeito da cirurgia em suas variáveis. OBJETIVOS: Avaliar os efeitos da plástica mitral nas variáveis do TCPE em pacientes com IM crônica. MÉTODOS: Foram selecionados 47 pacientes com IM grave e submetidos plástica da valva mitral, sendo nestes, realizado TCPE ± 30 dias antes da cirurgia, e de seis a 12 meses após a cirurgia. RESULTADOS: Houve predominância da classe funcional I ou II pela NYHA em 30 pacientes (63,8%) e 34 pacientes (72,3%), respectivamente. Após a cirurgia foi observado uma diminuição significativa do consumo de oxigênio (VO2), de 1.719 ± 571 para 1.609 ± 428 mL.min-1, p = 0,036. Houve redução do Oxygen Uptake Efficiency Slope (OUES), de 1.857 ± 594 para 1.763 ± 514, p = 0,073 e o pulso de oxigênio (O2) aumentou após a cirurgia, de 11,1 ± 3,2 para 11,9 ± 3,2 mL.bat-1 (p = 0,003). CONCLUSÃO: A plástica da valva mitral, não determinou aumento do VO2 pico e do OUES apesar do remodelamento cardíaco positivo observado após sete meses de cirurgia. Entretanto, o pulso de O2 aumentou no pós-operatório, sugerindo melhora do desempenho sistólico do VE. O TCPE é uma ferramenta útil, podendo auxiliar na conduta médica em pacientes com IM.


BACKGROUND: Mitral valve repair is the surgical procedure of choice for patients with chronic Mitral Regurgitation (MR). The good early and late results allow surgical indication before symptom onset. The cardiopulmonary exercise test (CPET) can objectively assess functional capacity, but little is known about the effect of surgery on their variables. OBJECTIVE: Evaluate the effects of mitral repair on CPET variables in patients with chronic MR. METHODS: A total of 47 patients with severe MR were selected; these patients underwent mitral valve repair and were submitted to CPET ± 30 days before surgery, as well as six to 12 months after the surgery. RESULTS: There was predominance of functional class I or II NYHA in 30 (63.8%) and 34 patients (72.3%), respectively. A significant decrease in oxygen consumption (VO2) was observed after surgery, from 1,719 ± 571 to 1609 ± 428 mL min-1, p = 0.036. There was a decrease in Oxygen Uptake Efficiency Slope (OUES) from 1,857 ± 594 to 1763 ± 514, p = 0.073 and oxygen pulse (O2) increased after surgery, from 11.1 ± 3.2 to 11.9 ± 3, 2 mL.beat-1 (p = 0.003). CONCLUSION: The mitral valve repair did not increase peak VO2 and OUES despite positive cardiac remodeling observed seven months after surgery. However, O2 pulse increased postoperatively, suggesting improved LV systolic performance. The CPET is a useful tool to assist in the medical management of patients with MR. (Arq Bras Cardiol. 2013; [online].ahead print, PP.0-0).


Subject(s)
Female , Humans , Male , Middle Aged , Exercise Test/methods , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Oxygen Consumption/physiology , Pulmonary Ventilation/physiology , Ventricular Function, Left/physiology , Chronic Disease , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency , Statistics, Nonparametric , Treatment Outcome
12.
Einstein (Säo Paulo) ; 10(4): 498-501, Oct.-Dec. 2012. ilus, tab
Article in English | LILACS | ID: lil-662483

ABSTRACT

Patients diagnosed with multiple myeloma are more susceptible to infections which are the major causes of morbidity and mortality associated to this disease. The main infectious agents involved are Gram-positive bacteria. However, after chemotherapy an increase in the incidence of Gram-negative strains is observed. These bacteria are also responsible for most cases of urinary tract infections. Here is reported a rare case in a 73-year-old man with multiple myeloma who developed endocarditis due to pseudomonas.


Pacientes diagnosticados com mieloma múltiplo são mais suscetíveis a infecções, que é a principal causa de morbidade e mortalidade associadas a essa doença. Os principais agentes infecciosos envolvidos são as bactérias Gram-positivas, mas, após a quimioterapia, pode haver aumento na incidência de Gram-negativos, que são responsáveis, na maioria dos casos, por infecções do trato urinário. Assim, descrevese um raro caso de um paciente de 73 anos de idade, com mieloma múltiplo diagnosticado com endocardite por pseudomonas.


Subject(s)
Aged , Humans , Male , Endocarditis, Bacterial/microbiology , Mitral Valve/microbiology , Multiple Myeloma/complications , Pseudomonas Infections/complications , Magnetic Resonance Spectroscopy
13.
Rev. bras. cardiol. invasiva ; 20(2): 213-218, abr.-jun. 2012. ilus
Article in English, Portuguese | LILACS, SES-SP | ID: lil-649576

ABSTRACT

A reoperação é o método de escolha para a correção de defeitos protéticos paravalvulares. A correção da regurgitação paravalvar mitral por via percutânea constitui uma alternativainteressante para casos selecionados. Relatamos dois casos com regurgitação paravalvar mitral, tratados por via percutânea, com prótese AmplatzerTM Vascular Plug III, guiados porecocardiograma transesofágico tridimensional. No primeiro caso, o paciente, com 55 anos de idade, já havia sido submetido a tratamento cirúrgico por cinco vezes (trocas valvaresaórtica e mitral) e evoluía com insuficiência cardíaca classe III da New York Heart Association (NYHA) e insuficiência mitral grave. No segundo caso, o paciente, com 76 anos deidade, tinha sido submetido a troca valvar aórtica por duas vezes, a última associada a troca valvar mitral, e evoluía em insuficiência cardíaca classe IV (NYHA) e regurgitação mitral grave, e várias comorbidades aumentavam seu risco cirúrgico. Os procedimentos foram realizados por via percutânea, sobanestesia geral, utilizando-se a via transeptal para o implante dos plugs, que ocluíram os defeitos paravalvares com sucesso em ambos os casos.


Subject(s)
Humans , Male , Middle Aged , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve/surgery , Echocardiography, Transesophageal/methods , Echocardiography, Transesophageal , Echocardiography, Three-Dimensional/methods , Echocardiography, Three-Dimensional
SELECTION OF CITATIONS
SEARCH DETAIL